1-AS/NZS 4026:2008 ELECTRIC CABLES-FOR UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS
4-PREFACE
5-CONTENTS
7-SECTION 1 SCOPE AND GENERAL
7-1.1 SCOPE
7-1.2 APPLICATION
7-1.3 REFERENCED DOCUMENTS
9-SECTION 2 POLYMERIC INSULATED 6.35/11(12) kV AND 12.7/22(24) kV DISTRIBUTION NETWORK CABLES
9-2.1 SCOPE OF SECTION
9-2.2 THREE-CORE CABLE
9-2.2.1 Construction
9-2.2.2 Conductors
9-2.2.3 Conductor screen
9-2.2.4 Insulation
9-2.2.5 Insulation screen
9-2.2.6 Metallic screen
10-2.2.7 Fillers and binder tapes
10-2.2.8 Composite oversheath
11-2.3 SINGLE-CORE CABLE
11-2.3.1 Construction
11-2.3.2 Conductors
11-2.3.3 Conductor screen
11-2.3.4 Insulation
11-2.3.5 Insulation screen
11-2.3.6 Metallic screen
11-2.3.7 Water blocking
11-2.3.8 Oversheath
12-2.4 TRIPLEX CABLE
12-2.4.1 Construction
12-2.4.2 Oversheath for cores of Triplex cable
12-2.5 MARKING OF CABLE
12-2.5.1 Cable identification
13-2.6 PREPARATION FOR DELIVERY
13-2.7 TESTS
13-2.8 CABLE OPTIONS
13-2.8.1 Water blocking of conductors
13-2.8.2 Larger metallic screen sizes
14-SECTION 3 PAPER INSULATED 6.35/11(12) kV DISTRIBUTION NETWORK CABLES
14-3.1 SCOPE OF SECTION
14-3.2 CONSTRUCTION
14-3.3 CONDUCTORS
14-3.4 IMPREGNATION
14-3.5 METAL SHEATH
14-3.6 NON-METALLIC SHEATH
14-3.6.1 Material
15-3.6.2 Thickness
15-3.7 MARKING OF CABLE
15-3.7.1 Core identification
15-3.7.2 Cable identification
15-3.7.3 Means of marking
15-3.8 MARKING OF DRUMS
15-3.9 PREPARATION FOR DELIVERY
15-3.10 TESTS
16-SECTION 4 XLPE INSULATED 0.6/1(1.2) kV DISTRIBUTION CABLES
16-4.1 SCOPE OF SECTION
16-4.2 CONSTRUCTION
16-4.3 CONDUCTORS
16-4.4 INSULATION
16-4.4.1 Material
16-4.4.2 Core identification
16-4.5 LAY°UP OF CORES
16-4.6 FILLERS AND BINDER TAPES
17-4.7 OVERSHEATH
17-4.7.1 Material
17-4.8 MARKING OF CABLE
17-4.8.1 Information to be marked
17-4.9 PREPARATION FOR DELIVERY
17-4.10 TESTS
18-SECTION 5 XLPE INSULATED 0.6/1(1.2) kV SERVICE CABLES
18-5.1 SCOPE OF SECTION
18-5.2 CONSTRUCTION
18-5.3 CONDUCTORS
18-5.4 INSULATION
18-5.4.1 Material
18-5.4.2 Thickness
18-5.4.3 Core identification
19-5.5 LAYING UP
19-5.6 FILLERS
19-5.7 COVERING
19-5.7.1 Material
19-5.7.2 Thickness
19-5.8 CABLE CROSS°SECTION
19-5.9 MARKING OF CABLE
19-5.9.1 Information to be marked
19-5.10 PREPARATION FOR DELIVERY
20-5.11 TESTS
21-APPENDIX A - CABLE DATA
21-A1 SCOPE
21-A2 CURRENT-CARRYING CAPACITY
21-A3 MAXIMUM PULLING TENSION
21-A4 MINIMUM BENDING RADIUS AND MINIMUM DIAMETER OF DRUM BARREL
22-A5 PAPER INSULATED CABLE EARTH FAULT CALCULATION
38-APPENDIX B - PURCHASING GUIDELINES
38-B1 SCOPE
38-B2 ITEMS TO BE SPECIFIED BY THE PURCHASER
38-B3 ITEMS SUBJECT TO AGREEMENT BETWEEN PURCHASER AND MANUFACTURER
39-APPENDIX C - SCREEN DETAILS FOR THREE-CORE POLYMERIC INSULATED 6.35/11 (12) kV AND 12.7/22 (24) kV DISTRIBUTION NETWORK...
39-C1 SCOPE