• -78%
  • New
AS/NZS 2201.1:2007
search
  • AS/NZS 2201.1:2007

AS/NZS 2201.1:2007

$172.01
$37.84 Save 78%

AS/NZS 2201.1:2007 Intruder alarm systems Client’s premises - Design, installation, commissioning and maintenance

Quantity

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

1-AS/NZS 2201.1:2007 INTRUDER ALARM SYSTEMS - CLIENTS PREMISES-DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
4-PREFACE
5-CONTENTS
7-SECTION 1 SCOPE AND GENERAL
7-1.1 SCOPE
7-1.2 APPLICATION
7-1.3 RISK ASSESSMENT
7-1.4 REFERENCED DOCUMENTS
8-1.5 DEFINITIONS
8-1.5.1 Alarmed area
8-1.5.2 Alarm condition
8-1.5.3 Alarm transmission equipment
9-1.5.4 Alarm warning device
9-1.5.5 Arming
9-1.5.6 Arming station
9-1.5.7 Client
9-1.5.8 Control equipment
9-1.5.9 Deliberately operated device
9-1.5.10 Detection circuits
9-1.5.11 Detection device
9-1.5.12 Disarming
9-1.5.13 Fault condition
9-1.5.14 Indicating equipment
9-1.5.15 Intruder alarm system
10-1.5.16 Monitored circuit
10-1.5.17 Monitoring centre
10-1.5.18 Partial arming/disarming
10-1.5.19 Power supply equipment
10-1.5.20 Remote access
10-1.5.21 Restricted key
10-1.5.22 Satellite siren
10-1.5.23 Security alarm company
10-1.5.24 Shell
10-1.5.25 System alarm
10-1.5.26 Tamper-detection device
10-1.5.27 Zone
11-SECTION 2 SYSTEM INSTALLATION REQUIREMENTS
11-2.1 GENERAL REQUIREMENTS
11-2.2 INSTALLATION
11-2.2.1 General
11-2.2.2 Control equipment and power supply location
11-2.2.3 Mounting
11-2.2.4 Tamper detection
11-2.2.5 Power supply equipment
11-2.2.6 Battery marking
12-2.2.7 Alarm transmission equipment
12-2.3 DETECTION DEVICES
12-2.3.1 General
12-2.3.2 Zoning
12-2.3.3 End-of-line supervision
12-2.4 AUDIBLE WARNING DEVICES
12-2.5 ENVIRONMENTAL CONDITIONS
12-2.5.1 General environmental conditions
12-2.5.2 Special environmental conditions
13-2.6 WIRING
13-2.6.1 General
13-2.6.2 Type of wiring
14-2.6.3 Stress on conductors and terminals
14-2.6.4 Protection of wiring
14-2.7 JOINTINGS
15-2.8 FLEXIBLE CONDUCTORS AND CONNECTIONS
15-2.9 TERMINATIONS
16-2.10 WIRE-FREE LINKS
16-2.11 COMMISSIONING
16-2.12 CLIENT TRAINING
17-SECTION 3 EQUIPMENT REQUIREMENTS
17-3.1 GENERAL REQUIREMENTS
17-3.2 ADDITIONAL FUNCTIONALITY
17-3.3 ENVIRONMENTAL CONDITIONS
17-3.4 ELECTROMAGNETIC CONFORMANCE COMPATIBILITY (EMC)
17-3.5 IMMUNITY
17-3.6 LOAD AND LINE CONDITIONS
17-3.6.1 Output overload
17-3.6.2 Input voltage variations
17-3.7 ENCLOSURES
17-3.8 TERMINALS
18-3.9 MARKING OF CONTROL EQUIPMENT
18-3.10 INSTRUCTIONS
18-3.11 POWER SUPPLIES
18-3.11.1 General
18-3.11.2 Performance
18-3.11.3 Low battery reporting
18-3.11.4 Automatic battery testing and fault reporting
19-3.11.5 Charger design
19-3.11.6 Charger rating
19-3.11.7 Mains supply isolation switch
19-3.12 POWER SUPPLY INDICATIONS
19-3.12.1 Mains indication
19-3.12.2 Charging indication
19-3.12.3 Battery indication
19-3.13 MARKING OF POWER SUPPLY EQUIPMENT
20-3.14 BATTERY REQUIREMENTS
20-3.14.1 General
20-3.14.2 Battery capacity
21-3.15 WIRE-FREE SYSTEMS
21-3.15.1 General
21-3.15.2 Immunity to in-band interference
21-3.15.3 Collision rate
22-3.15.4 Classification of wire-free systems
23-3.16 EQUIPMENT CLASSIFICATION
23-3.16.1 General
23-3.16.2 Class 1
26-3.16.3 Class 2
27-3.16.4 Class 3
28-3.16.5 Class 4
29-3.16.6 Class 5
30-SECTION 4 GENERAL OPERATIONAL PROCEDURES AND RESPONSIBILITIES
30-4.1 GENERAL RESPONSIBILITIES
30-4.2 CLIENT'S RESPONSIBILITIES
31-SECTION 5 MAINTENANCE AND SERVICE
31-5.1 SCOPE OF SECTION
31-5.2 MAINTENANCE
31-5.2.1 Routine maintenance
32-5.2.2 Emergency service
33-SECTION 6 RECORDS AND REPORTS
33-6.1 CLIENT AND EQUIPMENT RECORDS
33-6.2 MAINTENANCE RECORD
34-6.3 AUTHORITY FOR DISCONNECTING
34-6.4 LOGBOOK
35-APPENDIX A - APPLICATION TO RISK PROFILE
36-APPENDIX B - INDUSTRY TERMS
36-B1 DATA TRANSMISSION
36-B2 ENTRY/EXIT ROUTE
36-B3 INTERIOR
36-B4 ISOLATING
36-B5 MULTIPLEXING
36-B6 PERIMETER
37-APPENDIX C - STANDARDS RELATING TO BATTERIES AND BATTERY CHARGERS
37-C1 BATTERIES
37-C1.1 Galvanic cells and batteries in general
37-C1.2 Acid secondary cells and batteries
37-C1.3 Alkaline secondary cells and batteries
37-C1.4 Miscellaneous
37-C2 BATTERY CHARGERS
39-APPENDIX D - OCCUPANCY RATIO CALCULATIONS
39-D1 CALCULATION OF THE OCCUPATION RATIO OF THE MEDIUM BY SUPERVISORY SIGNALS
39-D2 CALCULATION OF THE OCCUPATION RATIO OF THE MEDIUM BY ALARM MESSAGES

R00002515
8579 Items
chat Comments (0)
No customer reviews for the moment.