1-AS 5079.1-2003 FILING CABINETS - LATERAL FILING CABINETS (ANSI BIFMA X5.2-1997, MOD)
4-PREFACE
5-CONTENTS
7-1 Scope
8-2 Definitions
8-2.1 acceptance level:
8-2.2 accessory item:
8-2.3 adjustable glides:
8-2.4 anti-rebound:
8-2.5 cabinet:
8-2.6 case:
8-2.7 caution label:
8-2.8 clear dimensions:
8-2.8.1 clear depth:
8-2.8.2 clear height:
8-2.8.3 clear width:
8-2.9 clear space:
8-2.10 closed:
8-2.11 compartments:
8-2.12 compressor:
8-2.13 counterweights:
8-2.14 cycle:
8-2.15 doors:
8-2.16 EDP extendible member:
9-2.17 extendible member:
9-2.18 force:
9-2.19 fully extended:
9-2.20 functional load:
9-2.21 ganging:
9-2.22 interlock:
9-2.23 lateral file:
9-2.24 lbf.:
9-2.25 leveled:
9-2.26 load:
9-2.27 lock:
9-2.28 loss of serviceability:
9-2.29 N (Newtons):
9-2.30 proof load:
9-2.31 pull:
9-2.32 stability:
9-2.33 stops:
9-2.34 suspension:
9-2.35 test platform:
9-2.36 tip over:
11-3 General
11-3.1 Types of Tests
11-3.2 Tolerances
11-3.3 Manufacturers Instructions
13-3.4 Loading Guidelines
13-3.4.1 Loading Material for Extendible Members
13-3.4.2 Loading Guidelines for Dynamic Testing of Extendible Members with Bottom Supported Loads
13-3.4.3 Loading Guidelines for Dynamic Testing of Extendible Members without Bottom Supported Loads.
15-3.5 Test Report Format
17-4 Retention Test
17-4.1 Purpose of Test
17-4.2 Test Setup
17-4.3 Test Procedure
17-4.4 Acceptance Level
19-5 Stability Tests
19-5.1 Purpose of Test
19-5.2 Test #1 Setup
19-5.3 Test # 1 - Procedure
21-5.4 Test #2 - Setup
21-5.5 Test #2 - Procedure
21-5.6 Acceptance Level for Test #1 and Test #2.
23-6 Rebound Test
23-6.1 Purpose of Test
23-6.2 Test Setup
23-6.3 Test Procedure
23-6.4 Acceptance Level
25-7 Out Stop Test
25-7.1 Purpose of Test
25-7.2 Test Setup
25-7.3 Test Procedure
25-7.4 Acceptance Level
27-8 Lock Test
27-8.1 Purpose of Test
27-8.2 Test Setup
29-8.3 Test Procedure
29-8.4 Acceptance Level
31-9 Extendible Member Cycle Test
31-9.1 Purpose of Test
31-9.2 Test Setup
33-9.3 Test Procedure
33-9.3.1 Cycling Test for Extendible Members with Clear Height < 305 mm (12 in.)
33-9.3.2 Cycling Tests for Extendible Members with Clear Height > 305 mm (12 in.)
35-9.4 Acceptance Level
37-10 Interlock Test
37-10.1 Purpose of Test
37-10.2 Test Setup
37-10.3 Test Procedure
37-10.4 Acceptance Level
39-11 Drop Test for Receding Door
39-11.1 Purpose of Test
39-11.2 Test Setup
39-11.3 Test Procedure
39-11.4 Acceptance Level
41-12 Cycling Test for Horizontal Receding Door
41-12.1 Purpose of Test
41-12.2 Test Setup
41-12.3 Test Procedure
41-12.4 Acceptance Level
43-13 Strength Test
43-13.1 Purpose of Test
43-13.2 Test Setup
43-13.3 Test Procedures
43-13.3.1 Top Functional Load Test
43-13.3.2 Top Proof Load Test
45-13.3.3 Shelf Functional Load Test
45-13.3.4 Shelf Proof Load Test
45-13.3.5 Extendible Member Proof Load Test
45-13.4 Acceptance Levels
45-13.4.1 Top Functional Load Test
45-13.4.2 Top Proof Load Test
45-13.4.3 Shelf Functional Load Test
45-13.4.4 Shelf Proof Load Test
45-13.4.5 Extendible Member Proof Load Test
47-14 Racking Resistance Test
47-14.1 Purpose of Test
47-14.2 Test Setup
47-14.3 Test Procedure
47-14.4 Acceptance Level
49-15 Pull Force Test
49-15.1 Purpose of Test
49-15.2 Test Setup
49-15.3 Test Procedure
49-15.4 Acceptance Level
50-APPENDIX ZZ - VARIATIONS TO ANSI BIFMA X5.2-1997 FOR AUSTRALIA
50-ZZ1 INTRODUCTION
50-ZZ2 VARIATIONS